Oscilloscope Mode (Vertical)Frequency Response - DC CoupledWithout probes and test leads (with BB12

Quantity
Add to wish list
Product description



  Oscilloscope Mode (Vertical)Frequency Response - DC CoupledWithout probes and test leads (with BB120): DC to 20 MHz (-3 dB)

  With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB)

  With VP41 10:1 probe: DC to 20 MHz (-3 dB)Frequency Response - AC Coupled (LF Roll Off)Without probes and test leads: <10 Hz (-3 dB)

  With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB)

  With VP41 10:1 probe: <10 Hz (-3 dB)Rise Time, Excluding Probes, Test Leads<17.5 nsInput ImpedanceWithout probes and test leads: 1 MΩ/20 pF

  With BB120: 1 MΩ/24 pF

  With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF

  With VP41 10:1 probe: 5 MΩ/15.5 pFSensitivity5 mV to 200 V/divAnalog Bandwidth Limiter10 kHzDisplay ModesA, -A, B, -BMaximum Input Voltage A and BDirect, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage

  With BB120: 600 VrmsMaximum Floating Voltage, from any Terminal to Ground600 Vrms CAT IV, 750 Vrms up to 400 HzOscilloscope Mode (Horizontal)Scope ModesNormal, single, rollRanges (Normal)Equivalent sampling: 20 ns to 500 ns/div

  Real time sampling: 1 μs to 5 s/div

  Single (real time): 1 μs to 5 s/div

  Roll (real time): 1 s to 60 s/divSampling Rate (for Both Channels Simultaneously)Equivalent sampling (repetitive signals): up to 4 GS/s

  Real time sampling 1 μs to 60 s/div: 40 MS/sTriggerScreen UpdateFree run, on triggerSourceA, BSensitivity A and BAt DC to 5 MHz: 0.5 divisions or 5 mV

  At 40 MHz: 4 divisionsSlopePositive, negativeAdvanced Scope FunctionsDisplay ModesNormal: Captures up to 25 ns glitches and displays analog-like persistence waveform

  Smooth: Suppresses noise from a waveform

  Glitch off: Does not capture glitches between samples

  Envelope: Records and displays the minimum and maximum of waveforms over timeAuto Set (Connect-and-View)Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger levelInput A and BDC Voltage (V DC)Ranges: 500 mV, 5, 50, 500, 750 V

  Accuracy: ±(0.5% +5 counts)

  Common mode rejection (CMRR): >100 dB at DC, >60 dB at 50, 60, or 400 Hz

  Full scale reading: 5000 countsTrue RMS Voltages (V AC and V AC+DC)Ranges: 500 mV, 5, 50, 500, 750 V

  Accuracy for 5 to 100% of range (DC coupled)

  DC to 60 Hz (V AC + DC): ±(1% +10 counts)

  1 to 60 Hz (V AC): ±(1% +10 counts)

  Accuracy for 5 to 100% of range (AC or DC coupled): 60 Hz to 20 kHz: ±(2.5% +15 counts)

  DC rejection (only V AC): >50 dB

  Common mode rejection (CMRR): >100 dB at DC; >60 dB at 50, 60, or 400 Hz

  Full scale reading: 5000 counts, reading is independent of any signal crest factorPeakModes: Maximum peak, minimum peak, peak-to-peak

  Ranges: 500 mV, 5, 50, 500, 2200 V

  Accuracy: Maximum peak or minimum peak: 5% of full scale; peak-to-peak: 10% of full scale

  Full scale reading: 500 countsFrequencyRanges: 1, 10, 100 Hz, 1, 10, 100 kHz, 1, 10, and 50 MHz

  Frequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset

  Accuracy at 1 Hz to 1 MHz: ±(0.5% +2 counts)

  Full scale reading: 10,000 countsRPMMaximum reading: 50 kRPM

  Accuracy: ±(0.5% +2 counts)Duty CycleRange: 2 to 98%

  Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autosetPulse WidthFrequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset

  Full scale reading: 1000 countsAmperesWith current clamp

  Ranges: same as V DC, V AC, V AC+DC, or peak

  Scale factors: 0.1, 1, 10, 100, 400 mV/A, 1 V/A, 10 mV/mA

  Accuracy: same as V DC, V AC, V AC+DC, or peak (add current clamp uncertainty)Decibel0 dBV: 1 V

  0 dBm (600/50 Ω): 1 mW referenced to 600 or 50 Ω

  dB on V DC, V AC, or V AC+DC

  Full scale reading; 1000 countsCrest FactorRange: 1 to 10

  Full scale reading: 90 countsPhaseModes: A to B, B to A

  Range: 0 to 359°

  Resolution: 1°VpwmPurpose: To measure on pulse width modulated signals, like motor drive inverter outputs

  Principle: Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency

  Accuracy: As Vrms for sine wave signalsInput A to CommonOhmRanges: 500 Ω, 5, 50, 500 kΩ, 5, 30 MΩ

  Accuracy: ±(0.6% +5 counts) 50 Ω ±(2% +20 counts)

  Full scale reading: 50 Ω to 5 MΩ - 5000 counts; 30 MΩ - 3000 counts

  Measurement current: 0.5 mA to 50 nA, decreases with increasing ranges

  Open circuit voltage: <4 VCommon Continuity (Cont)Beep: <(30 Ω ±5 Ω) in 50 Ω range

  Measurement current: 0.5 mA

  Detection of shorts of: ≥1 msCommon DiodeMeasurement voltage: At 0.5 mA: >2.8 V

  At open circuit: <4 V

  Measurement current: 0.5 mA

  Polarity: + on input A, - on COMCapacitance (CAP)Ranges: 50, 500 nF, 5, 50, 500 μF

  Full scale reading: 5000 counts

  Measurement current: 500 nA to 0.5 mA, increases with increasing rangesAdvanced Meter FunctionsZero SetSet actual value to referenceAutoHold (on A)Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signalsFixed Decimal PointActivated by using attenuation keysRecorderMeter ReadingsMeasurement speed: Maximum 2 measurements

  Record size (minimum, maximum, average): 2 M readings for 1 channel

  Recorded time span: 2 weeks

  Maximum number of events: 1024Waveform RecordMaximum sample rate: 400 K samples

  Size internal memory: 400 M samples recorded time

  Span internal memory: 15 minutes at 500 μs/div; 11 hours at 20 ms/div

  Record size SD card: 1.5 G samples

  Recorded time span SD card: 11 hours at 500 μs/div; 14 days at 20 ms/div

  Maximum number of events: 64General SpecificationsWaveform DisplayVertical: 10 div of 40 pixels

  Horizontal: 12 div of 40 pixelsMaximum Input Voltage A and BDirect on input or with leads: 600 Vrms CAT IV for derating

  With banana-to BNC adapter BB120: 600 Vrms for derating

  Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 HzDisplayType: 5.7" color active martrix TFT

  Resolution: 640 x 480InterfaceOptically isolated: Transfer screen copies (bitmaps), settings and data

  USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®Wireless Radio with AdapterFrequency range: 2412 to 2462 MHz

  Output power: <100 mWEnvironmentalMIL-PRF-28800F, Class 2TemperatureBattery operation: 32 to 104°F (0 to 40°C)

  Power adapter operation: 32 to 122°F (0 to 50°C)

  Storage: -4 to 140°F (-20 to 60°C) non-condensingHumidity (Operating)At 32 to 50°F (0 to 10°C): non-condensing

  At 50 to 86°F (10 to 30°C): 95%

  At 86 to 104°F (30 to 40°C): 75%

  At 104 to 122°F (40 to 50°C): 45%AltitudeOperating at 10,000' (3 km): CAT III 600 V

  Operating at 6600' (2 km): CAT IV 600 V

  Storage: 40,000' (12 km)EMC Electromagnetic CompatibilityUSA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103)Enclosure ProtectionIP51, ref: EN/IEC60529SafetyGeneral: IEC 61010-1: Pollution Degree 2

  Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 VMemoryInternal memory can store 20 data sets (screen waveform and setup)

  Micro SD card slot with optional SD card (maximum size of 32 GB)PowerExternal: Via power adapter BC430

  Input voltage: 10 to 21 V DC Consumption: 5 W typical

  Input connector: 5 mm jack

  Internal: Via battery pack BP290

  Battery power: Rechargeable Li-Ion 10.8 V

  Operating time: 7 hours with 50 % backlight brightness

  Charging time: 4 hours with test tool off, 7 hours with test tool on

  Allowable ambient temperature: 32 to 104°F (0 to 40°C) during chargingDimensions10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)Weight3.2 lbs (1.4 kg) including battery pack

Related products